Lanier Worldwide, Inc.
2300 Parklake Drive, NE
A
tlanta, GA USA 30345-2979
MATERIAL SAFETY DATA SHEET
Emergency Telephone: 800-551-3087
Section 1: Chemical Product and Company Information
Identity:
Black Toner Cartridge Type R1
MSDS No.
CP- 450
Product ID: 480-0285, 480-0393 Issued: 10/19/2006
Synonyms
& Common
Names:
Uses:
Chemical
Formula:
Black Toner Cartridge Type R1
Lanier LD328c, LD335c, LD345c,
LD435c, LD445c
Mixture
Supersedes:
Date:
Prepared by:
Approved by:
09/14/2005
10/19/2006
EH&S Department 770-496-9500
Larry Choskey, H&S Manager
Section 2: Composition / Information on Ingredients
PERCENT CAS No. EXPOSURE LIMITS SOURCE
Polyester resin > 70 Confidential Not listed N/a
Carbon black < 10 1333-86-4 3.5 mg/m
3
3.5 mg/m
3
OSHA TWA
ACGIH TWA
Wax < 10 Confidential Not listed N/a
Silica < 10 7631-86-9 15 mg/m
3
10 mg/m
3
OSHA TWA
ACGIH TWA
*PEL as the product: 15mg/m
3
(total dust), 5mg/m
3
(respirable dust)
*TLV as the product: 10mg/m
3
(total dust), 5mg/m
3
(respirable dust)
Section 3: Hazards Identification
HMIS Rating:
FLAMMABILITY = 1 HEALTH = 1
REACTIVITY = 0 SPECIAL = none
Health Hazards (Acute, Chronic, Immediate and Potential): Minimum irritation to respiratory tract may occur as with exposure
to any non-toxic dust. May cause gasping if inhaled. Inhalation should be avoided. May cause temporary eye discomfort.
Health Hazards of Long Term exposure (Chronic): Prolonged inhalation of excessive dust may cause lung damage. It is
attributed to “lung overloading”, a generic response to excessive amounts of any dust retained in the lungs for a prolonged interval.
Use of this product, as intended, does not result in inhalation of excessive dust.
Carcinogenicity: Carbon Black was reclassified as a Group 2B by the IARC in 1996 based upon the result of only the inhalation
study in rats. However, there was not observed the incidence of tumors on the test results on dermal or oral studies. Also, 2-years
inhalation study using a typical toner containing carbon black showed no association between toner exposure and animal tumors.
Section 4: First Aid Measures
Inhalation:
Gargle with water. Remove to fresh air if effects
occur. Get medical attention if needed.
Eye Contact:
In case of contact, immediately flush eyes
with water for 15 minutes. Get medical
attention if needed.
Skin Contact:
Wash with soap and water.
Ingestion:
Dilute stomach contents with several
glasses of water. Get medical attention.
Section 5: Fire Fighting Measures
Suitable extinguishing media: CO , dry chemical, foam or water.
2
Fire Fighting Instructions: Generally by sprinkling or extinguisher
Special protective equipment for fire fighters: none
UEL: n/a LEL: n/a
Burning rate: n/a
your document management partner
Seitenansicht 0
1 2 3

Inhaltsverzeichnis

Seite 1 - MATERIAL SAFETY DATA SHEET

Lanier Worldwide, Inc. 2300 Parklake Drive, NE Atlanta, GA USA 30345-2979 MATERIAL SAFETY DATA SHEET Emergency Telephone: 800-551-3087 Sec

Seite 2

MATERIAL SAFETY DATA SHEET Page 2 of 3 CP-450 Section 6: Accidental Release Measures Spill / leak Procedures: If spilled, sweep up us

Seite 3

MATERIAL SAFETY DATA SHEET Page 3 of 3 CP-450 Section 14: Transportation Information International regulations: RID/ADR Not applic

Kommentare zu diesen Handbüchern

Keine Kommentare