MATERIAL SAFETY DATA SHEET
Emergency Telephone: 800-526-4371
Section 1: Chemical Product and Company Information
Identity:
Toner Cartridge T1165
MSDS No.
FX-080
Product ID:
491-0321
Issued:
07/07/2005
Synonyms
& Common
Names:
Uses:
Chemical
Formula:
Toner Cartridge for
Lanier LF115 Fax
T1165
Lanier LF115 Fax
Mixture
Supersedes:
Date:
Prepared by:
Approved by:
European
Contact:
05/26/2003
07/07/2005
EH&S Department 770-496-9500
Larry Choskey, Manager, CEH&S
Walter Fricke, Manager, Safety &
Environment,
Lanier Worldwide, Inc.
Im Taubental D-41468 Neuss,
Germany +49-2131-387-177
Section 2: Composition / Information on Ingredients
PERCENT CAS No. EXPOSURE LIMITS SOURCE
Polyester resin 80-95 Confidential Not listed N/a
Carbon Black 6-7 1333-86-4 3.5 mg/m
3
3.5mg/m
3
N/a
Organic pigment <5 Confidential Not listed
N/a
*PEL as the product: 15mg/m
3
(total dust), 5mg/m
3
(respirable dust)
*TLV as the product: 10mg/m
3
(total dust), 5mg/m
3
(respirable dust)
Section 3: Hazards Identification
HMIS Rating:
FLAMMABILITY = 1 HEALTH = 1
REACTIVITY = 0 SPECIAL = none
Health Hazards (Acute, Chronic, Immediate and Potential): Minimum irritation to respiratory tract may occur as with exposure
to any non-toxic dust. May cause gasping if inhaled. Inhalation should be avoided. May cause temporary eye discomfort.
Health Hazards of Long Term exposure (Chronic): Prolonged inhalation of excessive dust may cause lung damage. It is
attributed to “lung overloading”, a generic response to excessive amounts of any dust retained in the lungs for a prolonged interval.
Use of this product, as intended, does not result in inhalation of excessive dust.
Carcinogenicity: Carbon Black was reclassified as a Group 2B by the IARC in 1996 based upon the result of only the inhalation
study in rats. However, there was not observed the incidence of tumors on the test results on dermal or oral studies. Also, 2-years
inhalation study using a typical toner containing carbon black showed no association between toner exposure and animal tumors.
Section 4: First Aid Measures
Inhalation:
Remove to fresh air. Gargle with water. Get medical
attention if needed.
Eye Contact:
In case of contact, immediately flush eyes with
water for 5 minutes. Get medical attention if
needed.
Skin Contact:
Wash with soap and water.
Ingestion:
Dilute stomach contents with several
glasses of water. Get medical attention.
Section 5: Fire Fighting Measures
Suitable extinguishing media: CO
2
, dry chemical, foam or water.
Extinguishing media which may not be used for safety
reasons: none
Special protective equipment for fire fighters: none
UEL: n/a LEL: n/a
your document management partner
Seitenansicht 0
1 2 3

Inhaltsverzeichnis

Seite 1 - MATERIAL SAFETY DATA SHEET

Lanier Worldwide, Inc. 2300 Parklake Drive, NE Atlanta, GA USA 30345-2979 MATERIAL SAFETY DATA SHEET Emergency Telephone: 800-526-4371 Sect

Seite 2

MATERIAL SAFETY DATA SHEET Page 2 of 3 FX-080 Section 6: Accidental Release Measures Spill / leak Procedures: If spilled, sweep up using a

Seite 3

MATERIAL SAFETY DATA SHEET Page 3 of 3 FX-080 Section 14: Transportation Information International regulations: RID/ADR Not applicable

Kommentare zu diesen Handbüchern

Keine Kommentare